| Name: | Synchronous Thermal Analyzer | Temperature Range: | Room Temperature ~ 1250 ° C |
|---|---|---|---|
| Temperature Resolution: | 0.1 °C | Heating Rate: | 1~80°C/min |
| Measuring Range: | 0 ~ ± 2000μV | Temperature Repeatability: | ± 0.1 ℃ |
| Highlight: | Synchronous Thermogravimetric Analyzer,Differential Thermogravimetric Analyzer,LCD Screen Thermogravimetric Analyzer |
||
BAXIT BXT-STA-200 Synchronous Thermal Analyzer
Product description:
Differential thermal analysis is a technique for measuring the temperature difference and temperature relationship between a substance and a reference substance under a program-controlled temperature. The differential thermal analysis curve describes the relationship between the temperature of the sample and the reference (ΔT) as a function of temperature or time. In the DTA test, the change in sample temperature is caused by the endothermic or exothermic effect of the phase transition or reaction. Such as: phase transformation, melting, crystal structure transformation, boiling, sublimation, evaporation, dehydrogenation reaction, fracture or decomposition reaction, oxidation or reduction reaction, destruction of lattice structure and other chemical reactions.
Instrument Features:
1. The instrument's main control chip uses the Cortex-M3 core ARM controller, which has faster processing speed and more accurate temperature control.
2. Using USB two-way communication, the operation is more convenient.
3. Adopt 7 inch 24bit full color LCD touch screen, the interface is more friendly.
4. Using nickel-chromium alloy sensor, more resistant to high temperature, corrosion and oxidation.
Technical Parameters:
| Temperature range | Room temperature ~ 1250 ℃ |
| Measuring range | 0 ~ ± 2000μV |
| DTA accuracy | 0.01μV |
| Heating rate | 1 ~ 80 ℃ / min |
| Temperature resolution | 0.1 ℃ |
| Temperature accuracy | ± 0.1 ℃ |
| Temperature repeatability | ± 0.1 ℃ |
| Temperature control | Temperature increase: program control, parameter adjustment can be made as required |
| Furnace structure | The furnace body adopts a top-open cover structure, which replaces the traditional lifting furnace body, with high accuracy and easy operation |
| Atmosphere control | automatic switching of internal programs |
| Data interface | Standard USB interface, supporting data cable and operating software |
| Parameter standard | Equipped with standard, with one-button calibration function, the user can correct the temperature by himself |
| Display mode | 24bit color 7 inch LCD touch screen display |
| Baseline adjustment | Users can adjust the baseline by the slope and intercept of the baseline |
| Working power | AC 220V 50Hz |
Product Picture:
![]()
![]()
![]()
![]()
![]()