Temperature Range: | Room Temperature~1250℃ | Temperature Resolution: | 0.01℃ |
---|---|---|---|
Temperature Fluctuation: | ±0.1℃ | Heating Rate: | 0.1~100℃/min |
Cooling Rate: | 1~20℃/min | Temperature Control Method: | Heating, Constant Temperature, Cooling |
Highlight: | TGA Synchronous Thermal Analyzer,Simultaneous Detection Thermal Analyzer,AC220V Synchronous Thermal Analyzer |
Product introduction:
Thermogravimetric analysis (TG, TGA) is the change of the mass of a sample with
temperature or time during temperature rise,constant temperature or temperature reduction.
The purpose is to study the thermal stability and composition of the material.
It is widely used in research and development, process optimization and
quality monitoring in various fields such as plastics, rubber, coatings,
pharmaceuticals, catalysts, inorganic materials, metal materials and composite materials.
Controller and software advantages:
Ⅰ. Imported 32bit ARM processor
Cortex-M3 core, sampling speed,
processing speed is faster.
Ⅱ. 24bit four-way sampling AD collects
DSC signals and TG signals and
temperature T signals.
Ⅲ. The power supply and water circulation
part is separately controlled by 8bit single-chip microcomputer, so that the main unit
and the cooling part are separated,
and they do not interfere with each other,
but the two are closely connected,
and the cooling
part is controlled by the host.
Ⅰ. Imported 32bit ARM processor Cortex-M3 core, sampling speed, processing speed is faster.
Spectrum analysis:
The following characteristics of the measurement and study materials:
DSC: melting, crystallization, phase change, reaction temperature and reaction heat, heat of combustion, specific heat.
TGA: thermal stability, decomposition, oxidation and reduction, adsorption desorption, free water and crystal water
content,composition ratio calculation.
TGA Results:
∙ Thermal stability
∙ Compositional analysis
∙ Mass changes
∙ Decomposition behavior
∙ Pyrolysis
∙ Water amount
∙ Identification of solvents
Thermogravimetric analysis, or TGA (also known as thermogravimetry, or TG)
measures the mass change of a substance while the sample is subjected to a controlledtemperature program.
“Top-loading arrangement”
simply means that the sample is located above the balance. This ensures safe and easy handling.
SIMULATIVE
OPTIMIZATION
OF DEBINDING
Figure 1:
Technical parameters:
Model | BXT-TGA-1250 | BXT-TGA-1600 |
Temperature range | Room temperature~1250℃ | Room temperature~1600℃ |
Temperature resolution | 0.01℃ | 0.01℃ |
Temperature fluctuation | ±0.1℃ | ±0.1℃ |
Heating rate | 0.1~100℃/min | 0.1~100℃/min |
Cooling rate | 1~20℃/min | 1~20℃/min |
Temperature control method | heating, constant temperature, cooling | heating, constant temperature, cooling |
Cooling time | 15min (1000℃…100℃) | 15min (1000℃…100℃) |
Measuring range of balance | 1mg~2g | 1mg~2g |
Resolution | 0.1μg | 0.1μg |
DSC range | 0~±500mW | 0~±500mW |
DSC resolution | 0.01mW | 0.01mW |
Constant temperature time | 0~300min arbitrarily set | 0~300min arbitrarily set |
Display mod | Chinese character large-screen LCD display | Chinese character large-screen LCD display |
Atmosphere | inert, oxidizing, reducing, static, dynamic | inert, oxidizing, reducing, static, dynamic |
Atmosphere device | Built-in gas flow meter, including two-way gas switching and flow rate control | Built-in gas flow meter, including two-way gas switching and flow rate control |
Software | Intelligent software can automatically record the TG curve for data processing and print experimental reports | Intelligent software can automatically record the TG curve for data processing and print experimental reports |
Data interface | Standard USB interface, special software (free software upgrades from time to time) | Standard USB interface, special software (free software upgrades from time to time) |
Power supply | AC220V 50Hz | AC220V 50Hz |
Features:
1. Furnace heating using nickel-cadmium alloy double-wound wire system to reduce interference, but also high temperature.
2. Tray sensor, using precious metal nickel-cadmium alloy Seiko build, with high temperature, anti-oxidation, corrosion resistance
and so on.
3. Power supply, circulation and cooling part of the host separate to reduce the heat and vibration on the microbalance impact.
4. Using open cover structure, easy to operate. Move the furnace body to put the sample operation is very difficult, easy to cause
the sample rod damage.
5. The host uses water thermostat to isolate the thermal effect of the heating furnace on the chassis and the microbolometer.
6. According to customer requirements to replace the furnace.
Company introduction:
If you encounter with any problems during the testing process,we promise providing urgent guidence and after-sales sevice within 48 hours and solution providing within 3 working days. If customers require on-site service, the transport and travel expense shall be responsible for the cost.
1. Pre-service
24 Hours online service for customers' consultation.
2. Middle service
-- Fullfill customer's request:
-- Payment method depends on customer.
-- Promptly production and delivery
-- Can provide invoice value if you want to decrease your tax.
3. After sale service
-- One year warranty service and all life maintenance.
-- Technical Egineer are avalible for oversea trainning.
-- Remote control technical consult