Accurate Flammability Testing Equipment , Multi Purpose Oxygen Index Tester

Basic Information
Place of Origin: Shanghai, China(mainland)
Brand Name: BAXIT
Model Number: GLO-HC2
Minimum Order Quantity: 1 PCS
Price: Negotiable
Packaging Details: Wooden box
Delivery Time: 5-8 days
Payment Terms: L/C, D/A, D/P, Western Union
Supply Ability: 10Set per day
Detail Information
Flow Adjustment Range: 0-10L/min(60-600 L/h ) Oxygen Input Pressure: >0.25Mpa
Measuring Range: 0~100%O2 Flow Meter: 0-10L/min(60-600 L/h )
Input Pressure: 0.2-0.3MPa Ambient Temperature: -10℃~45℃
High Light:

combustion testing equipment

,

flammability test apparatus


Product Description

Oxygen Index Tester


 

First, the scope of application:
Suitable for the determination of the burning properties of plastics, rubber, fiber, foam, film and film and textile materials


Second, the main technical parameters:
Flow meter display
2. Machine accuracy: 2.5
3. Flow adjustment range: 0-10L/min (60-600 L/h)
4. Oxygen input pressure: >0.25Mpa
5. Measurement range: 0 ~ 100% O2;
6. Combustion tube: inner diameter ≥75mm total 450mm
7. Gas flow rate in the combustion cylinder: 40mm ± 2mm / s
8. Pressure gauge accuracy 2.5
9. Flowmeter: 0-10L/min (60-600 L/h) adjustable
10. Test environment: temperature 10-35 ° C, humidity 45-75%
11. Input pressure: 0.2-0.3MPa
12. Working pressure: nitrogen 0.1-0.15Mpa oxygen 0.1-0.15Mpa
13. Oxygen/nitrogen mixed gas inlet: including regulator valve, flow regulating valve, gas filter and mixing chamber
14. Sample holders can be used for soft and rigid plastics, textiles, fire doors, etc.
15. Propane (butane) ignition system, flame length 5mm-60mm can be adjusted freely
16. Gas: Industrial grade oxygen/nitrogen (user-supplied).
17. Igniter: It has a metal tube and a nozzle with an inner diameter of Φ2±1mm at the end. It can be inserted into the combustion cylinder to ignite the sample.
18. Self-supporting material sample holder: can be fixed at the axial position of the combustion tube and can clamp the sample vertically
19. Non-self-supporting material sample holder: all stainless steel, can fix the two vertical sides of the sample on the frame at the same time


Working conditions of HC-2 oxygen index meter
1. Ambient temperature: -10 ° C ~ 45 ° C
2. Relative humidity: <85%;
3 Use gas: GB3863 industrial gaseous oxygen; GB3864 industrial gaseous nitrogen; both bottles of gas should be pressure regulating valve;
5. Input pressure: 0.25-0.4Mpa;
6. Working pressure: 0.15Mpa;

Design standard: GB/T 2406-1993
Compliance with standards: ASTM D 2863, ISO 4589-2, NES 714 GB/T 5454 GB/T 10707 GB/T 8924-1988 GB/T 16581-1996 IEC 61144-1992


Fourth, product configuration
Host 1
2. Ignition 1
3. Glass tube 2
4. Glass beads 1 bag (into the combustion column)
5. Nylon tube Ф 4 1.2 m (connecting the combustion column to the main unit)
6. Sealing ring Several (already placed on the Ф4 tube)
7. Tip sample holder 1 set
8. One metal mesh (into the combustion column)
9. 1 plastic outlet plate (already placed in the combustion tube)
10. Rubber hose 2
11. M10×1 inner joint screw 1 (within the combustion column)
12. M10×1 joint nut 1 piece (connected to the main unit)
13. Instructions 1 copy