Temperature Repeatability: | ± 0.1 ℃ | Temperature Control: | Temperature Increase&constant Temperature |
---|---|---|---|
Furnace Structure: | Top-open Cover Structure | Atmosphere Control: | Automatic Switching Of Internal Programs |
Data Interface: | Standard USB Interface, Supporting Data Cable And Operating Software | Baseline Adjustment: | Users Can Adjust The Baseline By The Slope And Intercept Of The Baseline |
High Light: | Dta Differential Thermal Analysis Equipment,1150C Differential Thermal Analysis Equipment,LCD Differential Thermal Analysis Equipment |
Product description:
Differential thermal analysis is a technique for measuring the temperature difference and temperature relationship between a substance and a reference substance under a program-controlled temperature. The differential thermal analysis curve describes the relationship between the temperature of the sample and the reference (ΔT) as a function of temperature or time. In the DTA test, the change in sample temperature is caused by the endothermic or exothermic effect of the phase transition or reaction. Such as: phase transformation, melting, crystal structure transformation, boiling, sublimation, evaporation, dehydrogenation reaction, fracture or decomposition reaction, oxidation or reduction reaction, destruction of lattice structure and other chemical reactions.
Standard:
GB/T 19466.2-2004 / ISO 11357-2: 1999 Part 2: Determination of glass transition temperature;
GB/T 19466.3-2004 / ISO 11357-3: 1999 Part 3: Determination of melting and crystallization temperature and enthalpy;
GB/T 19466.6-2009/ISO 11357-3:1999 Part 6 Oxidation induction period Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT).
Instrument Features:
1. New fully enclosed advanced ceramic furnace design structure.
2. The sensor is more corrosion resistant, oxidation resistant, sensor sensitivity is high.
3. Adopts ARM controller based on Cortex-M3 kernel.
4. USB fully realize intelligent operation.
5. The touch screen displays the status and data of the instrument in real time.
6. The whole process of automatic instrument drawing, software can realize a variety of data processing.
Technical Parameters:
Temperature range | room temperature ~ 1150 ℃ |
Measuring range | 0 ~ ± 2000μV |
DTA accuracy | 0.01μV |
Heating rate | 1 ~ 80 ℃ / min |
Temperature resolution | 0.1 ℃ |
Temperature accuracy | ± 0.1 ℃ |
Temperature repeatability | ± 0.1 ℃ |
Temperature control |
temperature increase: program control, parameter adjustment can be made as required Constant temperature: Program control Constant temperature time can be set arbitrarily |
Furnace structure | The furnace body adopts a top-open cover structure, which replaces the traditional lifting furnace body, with high accuracy and easy operation. |
Atmosphere control | automatic switching of internal programs |
Data interface | standard USB interface, supporting data cable and operating software |
Display mode | 24bit color 7 inch LCD touch screen display |
Parameter standard | Equipped with standard, with one-button calibration function, the user can correct the temperature by himself |
Baseline adjustment | users can adjust the baseline by the slope and intercept of the baseline |
Working power | AC 220V 50Hz |