logo
Send Message
products

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers.

Basic Information
Place of Origin: china
Brand Name: BAXIT
Model Number: BXT-AAS4HS
Minimum Order Quantity: 1
Price: USD 11030-13510/unit
Packaging Details: wooden box
Delivery Time: 3-5working days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 1000units
Detail Information
Classification: Flame Graphite Integrated Machine (4Lamp Positions) Model: BXT-AAS4HS
Detector: Hamamatsu Photomultiplier Tube From Japan Wavelength Range: (185-900)nm
Wavelength Indication Error: ≤±0.1nm Wavelength Repeatability: ≤±0.025nm
Baseline Drift: 0.001ABS/30min(Static) 0.003ABS/15min(Dynamic) Light Source System: Rotary Turret-type Fully Automatic Switching Lamp Holder
Element Lamp Lighting Mode: 400Hz, 1/4 Duty Cycle Pulse Is On Monochromator: Czerny-Turner Enhanced Type
Grating Line Density: 1800 Spectral Bandwidth: 0nm、0.1nm、0.2nm、0.4nm、1.0nm、2.0nm Multi-gear Automatic Switching
Flame Atomization System: Standard Equipment Burner: 0.5mmx100mmAll-titanium Combustion Head
Sprayer: Metal Sleeve High-efficiency Glass Spray Nozzle Atomization Chamber: Corrosion-resistant All-plastic Atomization Chamber
Repetition: RSD≤0.7% Detection Limit: 1.5pg
Safety Protection: Pressure System Failure Protection, Cooling System Failure Protection, Real-time Power Monitoring Sample Size: 1-99
Result Output: Multi-format Data Storage And Print Output Communication Interface: RS232, USB Expansion Interface
Host Machine Size: 1000x400x470mm Graphite Furnace Atomic Absorption System: Standard Configuration
Precision: ≤3% Heating Temperature Range: Room Temperature-3000℃
Heating Speed: 2000 Degrees Per Second Temperature Control Accuracy: 1%
Heating Conditions Setting: 11 Step, Ramp Temperature Rise, Stepwise Temperature Rise, Maximum Power Temperature Rise, Temperature Rise Monitoring Opposite-side System Background Correction (deuterium Lamp): When Using 1ABS, The Value Should Be ≥ 60 Times.
Highlight:

900 nanometers Atomic Absorption Spectrophotometer

,

190 nanometers Atomic Absorption Spectrophotometer

,

Laboratory Flame Atomic Absorption Spectrophotometer


Product Description

Atomic Absorption Spectrophotometer

Atomic absorption spectrophotometer can be widely applied in various industries such

as geology, metallurgy, medicine, chemical engineering, petroleum, agriculture, environmental

protection and commodity inspection. The application of it for the analysis of trace and ultra-trace

elements has gradually shifted from inorganic chemistry to organic chemistry in recent years.

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers. 0

 

Working principle

The characteristic spectral radiation of the element to be measured is emitted by the light

source and absorbed by the ground-state atoms of the element to be measured in the vapor

of the sample produced by the atomizer such as a flame or graphite furnace. The content of

the element to be measured is determined by measuring the amount of the characteristic

spectral radiation absorbed.

 

Classification Flame type
(4,6,8Lamp Positions)
Flame Graphite Integrated Machine
(4,6Lamp Positions)
Fully automatic flame graphite integrated machine
(8Lamp Positions)
Model BXT-AAS4H
BXT-AAS6H
BXT-AAS8H
BXT-AAS4HS
BXT-AAS6HS
BXT-AAS8HS-P
Detector Hamamatsu Photomultiplier Tube from Japan
wavelength range (190-900)nm (185-900)nm
Wavelength indication error ≤±0.1nm
Wavelength repeatability ≤±0.025nm
Baseline drift 0.001ABS/30min(Static) 0.003ABS/15min(Dynamic)
Light source system Rotary turret-type fully automatic switching lamp holder
Element lamp
Lighting mode
400Hz, 1/4 duty cycle pulse is on
Monochromator Czerny-Turner Enhanced type
Grating line density 1800
Spectral bandwidth 0nm,0.1nm,0.2nm,0.4nm,1.0nm,2.0nm Multi-gear automatic switching
Atomizer Flame atomizer
Flame atomization system Standard equipment
Burner 0.5mmx100mmAll-titanium combustion head
Sprayer Metal sleeve high-efficiency glass spray nozzle
Atomization chamber Corrosion-resistant all-plastic atomization chamber
Repetition RSD≤0.7%
Detection limit (Cu)<0.006ug/ml
Safety protection It has multiple safety protection functions, including alarm for acetylene leakage and system shutdown.
Graphite Furnace Atomic Absorption System No Standard configuration
Detection limit No 1.5pg
Precision No ≤3%
Heating temperature range No Room temperature-3000℃
Heating speed No 2000 degrees per second
Temperature control accuracy No 1%
Heating conditions setting No 11 step, ramp temperature rise, stepwise temperature rise, maximum power temperature rise, temperature rise monitoring opposite-side system
Safety protection No Pressure system failure protection, cooling system failure protection, real-time power monitoring
Background correction (deuterium lamp) No When using 1ABS, the value should be ≥ 60 times.
Background correction No When using 1ABS, the value should be ≥ 60 times.
Automatic sample introduction system No 85 channels, automatic calibration curve configuration, automatic dilution function, high-precision injection
Sample size 1-99
Result output Multi-format data storage and print output
Communication interface RS232, USB expansion interface
Host machine size 1000x400x470mm 1030x430x400mm
Weight(kg) 75 120 130

 

 

 

Applicable scenarios

 

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers. 1

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers. 2

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers. 3

Product detail illustration

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers. 4

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers. 5

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers. 6

Contact Details
Clarke

Phone Number : +8615001723665

WhatsApp : +8615001723665