| Name: | Ultra-Micro Spectrophotometer | Detection Module: | Microvolume Nucleic Acid/Protein Detection + OD600 Bacterial Culture Detection + Fluorescence Nucleic Acid Detection |
|---|---|---|---|
| Wavelength Range: | 230nm、260nm、280nm (Three-Wavelength) | Sample Volume: | 0.5~2μL |
| Path Length: | 0.2mm, 0.04mm (High-Concentration), 1.0mm (Routine) | Light Source: | Xenon Flash Lamp |
| Detector: | UV-Enhanced CMOS Linear Array Sensor | Nucleic Acid Detection: | 2~15000ng/μL (dsDNA) |
| Protein Detection: | 0.05~400mg/mL (BSA) | Absorbance Precision: | 0.003Abs (0.2mm Path Length) |
| Absorbance Accuracy: | ±2% (0.76Abs @ 260nm) | Absorbance Range: | 0.04~300A (Equiv. 10mm Path Length) |
| Detection Time: | <6s | OD600 Absorbance Range: | 0~4 Abs |
| OD600 Stability/Repeatability: | ≤1% | Fluorescence Linearity: | R²>0.995 |
| Fluorescence Repeatability/Stability: | <1.5% | Data Storage: | 1~100,000 Records; Query, Print, USB Export, Upload To Platform |
| Power Adapter: | 45W Fast Charging | Battery Capacity: | 21.6V 7000mAh |
| Power Consumption: | 25W (Standby: 10W) | Dimensions & Weight: | 325mm*227mm*211mm;5.15kg |
| Highlight: | Ultra-micro spectrophotometer nucleic acid analyzer,OD600 bacterial fluorescence detector,Laboratory protein analyzer equipment |
||
Produt Introduction:
The GLOMRO Ultra-micro Spectrophotometer is a high-precision biological detection instrument based on UV-Vis spectrophotometry, designed for rapid concentration and purity analysis of nucleic acids (DNA/RNA), proteins, cell lysates, and other biological samples at extremely low sample volumes (0.5~2 μL).
The instrument uses liquid column surface tension technology, requiring no cuvettes or capillaries. Detection is completed with only 0.5~2μL of sample in under 6 seconds. It is widely applicable in life science research, biopharmaceuticals, medical diagnostics, and food safety.
Multiple Detection Modules:
1. Microvolume Nucleic Acid/Protein Detection
l Wavelength range: 230nm, 260nm, 280nm (three-wavelength model); 190~850nm (full-wavelength model)
l Nucleic acid detection range: 2~15,000 ng/μL (dsDNA)
l Protein detection range: 0.05~400 mg/mL (BSA)
2. OD600 Bacterial Culture Detection
l Equipped with OD600 optical path detection system and cuvette detection module
l Directly measures bacterial culture concentration
l Absorbance range: 0~4 Abs; stability/repeatability ≤ 1%
3. Fluorescence Nucleic Acid Quantification
l Fluorescent dyes specifically bind to target substances
l DNA/RNA detection limit as low as 0.5 pg/μL (dsDNA)
lLinearity R² > 0.995; repeatability/stability < 1.5%
![]()
![]()
| Model | GLO-CWF1 | GLO-CWF2 | GLO-CWF3 | GLO-CWF4 |
| Detection Module | Microvolume Nucleic Acid/Protein Detection + OD600 Bacterial Culture Detection | Microvolume Nucleic Acid/Protein Detection + OD600 Bacterial Culture Detection + Fluorescence Nucleic Acid Detection | Microvolume Nucleic Acid/Protein Detection + OD600 Bacterial Culture Detection | Microvolume Nucleic Acid/Protein Detection + OD600 Bacterial Culture Detection + Fluorescence Nucleic Acid Detection |
| Wavelength Range | 230nm,260nm,280nm (Three-Wavelength) | 190~850nm (Full Wavelength) | ||
| Sample Volume | 0.5~2μL | |||
| Path Length | 0.2mm, 0.04mm (High-Concentration), 1.0mm (Routine) | |||
| Light Source | Xenon Flash Lamp | |||
| Detector | UV-Enhanced CMOS Linear Array Sensor | |||
| Nucleic Acid Detection | 2~15000ng/μL (dsDNA) | |||
| Protein Detection | 0.05~400mg/mL (BSA) | |||
| Absorbance Precision | 0.003Abs (0.2mm Path Length) | |||
| Absorbance Accuracy | ±2% (0.76Abs @ 260nm) | |||
| Absorbance Range | 0.04~300A (Equiv. 10mm Path Length) | |||
| Detection Time | <6s | |||
| OD600 Absorbance Range | 0~4 Abs | |||
| OD600 Stability | ≤1% | |||
| OD600 Repeatability | ≤1% | |||
| Fluorescence Linearity | / | R²>0.995 | / | R²>0.995 |
| Fluorescence Repeatability | / | <1.5% | / | <1.5% |
| Fluorescence Stability | / | <1.5% | / | <1.5% |
| Data Storage | 1~100,000 Records; Query, Print, USB Export, Upload to Platform | |||
| Power Adapter | 45W Fast Charging | |||
| Battery Capacity | 21.6V 7000mAh | |||
| Power Consumption | 25W (Standby: 10W) | |||
| Dimensions & Weight | 325mm*227mm*211mm;5.15kg | |||
FAQ
1. Who are we?
We are based in Shanghai, China, start from 2017,sell to North America(20.00%),Western Europe(15.00%),South America(10.00%),Oceania(10.00%),Northern Europe(10.00%),Eastern Europe(10.00%),South Asia(5.00%),Southern Europe(5.00%),Central America(5.00%),Africa(5.00%),Southeast Asia(5.00%). There are total about 5-10 people in our office.
2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3.What can you buy from us?
Differential Scanning Calorimeter, Thermogravimetric Analyzer, Differential Thermal Analyzer, Oxygen Bomb Calorimeter, Spot Cooler
4. Why should you buy from us not from other suppliers?
We have 10 years of experience in design and development. The price preferential benefit There is a lot of goods in stock The service is good
5. What services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,FAS,CIP,FCA,DDU,Express Delivery,DAF;
Accepted Payment Currency:USD;
Accepted Payment Type: T/T,Credit Card,Western Union;
Language Spoken:English,Chinese