logo
products

Ultra-micro Spectrophotometric Nucleic Acid Protein Analyzer, OD600 Bacterial Liquid Fluorescence Detection Laboratory Equipment

Basic Information
Place of Origin: China
Brand Name: GLOMRO
Model Number: GLO-CWF2
Minimum Order Quantity: 1
Price: US $4651.0 / Piece
Packaging Details: Carton box/Wooden box
Delivery Time: 3-5 work day
Payment Terms: L/C,D/A,D/P,T/T
Supply Ability: 1000pcs
Detail Information
Name: Ultra-Micro Spectrophotometer Detection Module: Microvolume Nucleic Acid/Protein Detection + OD600 Bacterial Culture Detection + Fluorescence Nucleic Acid Detection
Wavelength Range: 230nm、260nm、280nm (Three-Wavelength) Sample Volume: 0.5~2μL
Path Length: 0.2mm, 0.04mm (High-Concentration), 1.0mm (Routine) Light Source: Xenon Flash Lamp
Detector: UV-Enhanced CMOS Linear Array Sensor Nucleic Acid Detection: 2~15000ng/μL (dsDNA)
Protein Detection: 0.05~400mg/mL (BSA) Absorbance Precision: 0.003Abs (0.2mm Path Length)
Absorbance Accuracy: ±2% (0.76Abs @ 260nm) Absorbance Range: 0.04~300A (Equiv. 10mm Path Length)
Detection Time: <6s OD600 Absorbance Range: 0~4 Abs
OD600 Stability/Repeatability: ≤1% Fluorescence Linearity: R²>0.995
Fluorescence Repeatability/Stability: <1.5% Data Storage: 1~100,000 Records; Query, Print, USB Export, Upload To Platform
Power Adapter: 45W Fast Charging Battery Capacity: 21.6V 7000mAh
Power Consumption: 25W (Standby: 10W) Dimensions & Weight: 325mm*227mm*211mm;5.15kg
Highlight:

Ultra-micro spectrophotometer nucleic acid analyzer

,

OD600 bacterial fluorescence detector

,

Laboratory protein analyzer equipment


Product Description

Ultra-micro Spectrophotometer

Produt Introduction:

The GLOMRO Ultra-micro Spectrophotometer is a high-precision biological detection instrument based on UV-Vis spectrophotometry, designed for rapid concentration and purity analysis of nucleic acids (DNA/RNA), proteins, cell lysates, and other biological samples at extremely low sample volumes (0.5~2 μL).

The instrument uses liquid column surface tension technology, requiring no cuvettes or capillaries. Detection is completed with only 0.5~2μL of sample in under 6 seconds. It is widely applicable in life science research, biopharmaceuticals, medical diagnostics, and food safety.


Multiple Detection Modules:

1. Microvolume Nucleic Acid/Protein Detection

l Wavelength range: 230nm, 260nm, 280nm (three-wavelength model); 190~850nm (full-wavelength model)

l Nucleic acid detection range: 2~15,000 ng/μL (dsDNA)

l Protein detection range: 0.05~400 mg/mL (BSA)

2. OD600 Bacterial Culture Detection

l Equipped with OD600 optical path detection system and cuvette detection module

l Directly measures bacterial culture concentration

l Absorbance range: 0~4 Abs; stability/repeatability ≤ 1%

3. Fluorescence Nucleic Acid Quantification

l Fluorescent dyes specifically bind to target substances

l DNA/RNA detection limit as low as 0.5 pg/μL (dsDNA)

lLinearity R² > 0.995; repeatability/stability < 1.5%


Ultra-micro Spectrophotometric Nucleic Acid Protein Analyzer, OD600 Bacterial Liquid Fluorescence Detection Laboratory Equipment

Ultra-micro Spectrophotometric Nucleic Acid Protein Analyzer, OD600 Bacterial Liquid Fluorescence Detection Laboratory Equipment

Model GLO-CWF1 GLO-CWF2 GLO-CWF3 GLO-CWF4
Detection Module Microvolume Nucleic Acid/Protein Detection + OD600 Bacterial Culture Detection Microvolume Nucleic Acid/Protein Detection + OD600 Bacterial Culture Detection + Fluorescence Nucleic Acid Detection Microvolume Nucleic Acid/Protein Detection + OD600 Bacterial Culture Detection Microvolume Nucleic Acid/Protein Detection + OD600 Bacterial Culture Detection + Fluorescence Nucleic Acid Detection
Wavelength Range 230nm,260nm,280nm (Three-Wavelength) 190~850nm (Full Wavelength)
Sample Volume 0.5~2μL
Path Length 0.2mm, 0.04mm (High-Concentration), 1.0mm (Routine)
Light Source Xenon Flash Lamp
Detector UV-Enhanced CMOS Linear Array Sensor
Nucleic Acid Detection 2~15000ng/μL (dsDNA)
Protein Detection 0.05~400mg/mL (BSA)
Absorbance Precision 0.003Abs (0.2mm Path Length)
Absorbance Accuracy ±2% (0.76Abs @ 260nm)
Absorbance Range 0.04~300A (Equiv. 10mm Path Length)
Detection Time <6s
OD600 Absorbance Range 0~4 Abs
OD600 Stability ≤1%
OD600 Repeatability ≤1%
Fluorescence Linearity / R²>0.995 / R²>0.995
Fluorescence Repeatability /  <1.5% /  <1.5%
Fluorescence Stability /  <1.5% /  <1.5%
Data Storage 1~100,000 Records; Query, Print, USB Export, Upload to Platform
Power Adapter 45W Fast Charging
Battery Capacity 21.6V 7000mAh
Power Consumption 25W (Standby: 10W)
Dimensions & Weight 325mm*227mm*211mm;5.15kg

FAQ

1. Who are we?
We are based in Shanghai, China, start from 2017,sell to North America(20.00%),Western Europe(15.00%),South America(10.00%),Oceania(10.00%),Northern Europe(10.00%),Eastern Europe(10.00%),South Asia(5.00%),Southern Europe(5.00%),Central America(5.00%),Africa(5.00%),Southeast Asia(5.00%). There are total about 5-10 people in our office.

2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;

3.What can you buy from us?
Differential Scanning Calorimeter, Thermogravimetric Analyzer, Differential Thermal Analyzer, Oxygen Bomb Calorimeter, Spot Cooler

4. Why should you buy from us not from other suppliers?
We have 10 years of experience in design and development. The price preferential benefit There is a lot of goods in stock The service is good

5. What services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,FAS,CIP,FCA,DDU,Express Delivery,DAF;
Accepted Payment Currency:USD;
Accepted Payment Type: T/T,Credit Card,Western Union;
Language Spoken:English,Chinese

Contact Details
Clarke

Phone Number : +8615001723665

WhatsApp : +8615001723665