| Model Number: | XUIC-600-C | Vessel Volume: | ≤1.0μL |
|---|---|---|---|
| Baseline Noise: | ≤0.2%FS | Detector Temperature Control Range: | Room Temperature~60℃ |
| Temperature Control Accuracy: | Accuracy±0.1℃ | Maximum Operating Pressure: | 4000psi |
| Minimum Detectable Concentration: | C1-≤0.001 μg/mL | ||
| Highlight: | ion chromatography instrument price,laboratory chromatography analytical instruments,industrial ion chromatography equipment |
||
Ion chromatograph
All-in-One Ion Chromatography System XUIC-600 for Anions and Cations
XUIC-600 Ion Chromatograph with ≤0.5% Qualitative Repeatability
Product information
![]()
Technical Specifications
| Appearance structure | Overall dimensions | 360mm*430mm*488mm,Box-type design, with a built-in temperature control box |
| Function configuration | Double piston high-pressure constant current pump, imported mechanical six-way valve, built-in column temperature box, independent detector temperature control system, electrochemical membrane self-regeneration inhibitor, bipolar conductivity detector, V1.0 control system (can be upgraded to V3.0 system) etc | |
| Double-plunger high-pressure constant-flow pump | Pump pressure resistance | ≥35Mpa(5000psi) |
| Flow range | 0.001—9.999ml/min | |
| Flow accuracy | ≤0.1% | |
| Traffic repetition | RSD≤0.01% | |
| Material | Quartz plunger rod, high-pressure sealing ring, Peek pump head, resistant to acids, alkalis, organic solvents and high pressure, excellent sealing performance, long service life | |
| Pressure monitoring | Real-time monitoring system pressure | |
| Over-limit alarm self-protection | When the system pressure exceeds the set value, an alarm will sound and the operation will be automatically stopped | |
| Temperature control box | Structure | Built-in temperature control box, with a design featuring a continuous constant-temperature mode and an independent heating and temperature control system |
| Temperature compensation | Room temperature—80℃ | |
| Temperature control accuracy | ±0.1℃ | |
| Detector | Type | The bipolar conductivity detector is highly sensitive and has an independent temperature control system. |
| Temperature compensation | Room temperature—60℃ | |
| Temperature control accuracy | ±0.1℃ | |
| Baseline noise | ≤0.5%FS | |
| Baseline drift | ≤10.0%FS/30min | |
| Minimum detectable concentration | CL-≤0.001μg/ml Li+≤0.0005μg/ml | |
| Qualitative repeatability | ≤0.5% | |
| Quantitative repeatability | ≤2.0% | |
| Suppressor | Regeneration mode | The electrochemical membrane can self-recover, eliminating the need to replace the inhibiting agent and adding acid. It is convenient to use and has a quick balance |
| Inhibitory capacity | ≥100μeq, with high inhibition efficiency, suitable for gradient elution | |
| Dead volume | ≤80μL, higher sensitivity, faster reaction | |
| Compatibility | Anion inhibitor is compatible with hydroxide system and carbonate, bicarbonate systems;Cation inhibitor is compatible with mesylate system, nitrate system, oxalate system, etc | |
| Thermostat for the suppressor | Synchronized temperature control with the detector, resistant to external interference, quick equilibrium, small drift, more stable | |
| Control system | Communication | RS232 communication, parameter self-saving and reading, real-time data acquisition and transmission, multiple ports can be simultaneously established for communication |
| One-click power on/off | Abandon the cumbersome manual start-up and shutdown steps, start-up and shutdown can be automatically completed in one click | |
| One-click automatic maintenance | Click the maintenance button, automatically perform maintenance, solve the problem of cumbersome maintenance | |
| Self-protection | The system automatically starts the protection program after losing liquid, avoiding damage to accessories due to liquid loss | |
| Workstation V3.0 | Automatic system configuration | Automatically scans the chromatograph, injector, and other related configurations, automatically configures the system |
| User Management | Different users can be added, and corresponding permissions and passwords can be set for different users | |
| Sequence Management | Create and edit sequences, freely set sample names, properties, locations, injection volumes, etc | |
| Automatic shutdown | Free to choose between two automatic shutdown modes: automatic shutdown after sequence completion and timed shutdown | |
| Automatic printing | After the sequence is completed, an automatic detection report can be generated and printed automatically | |
| Data collection | There are two sample injection methods: single-run and batch-run. There are three triggering modes: injector trigger, software trigger, and valve trigger. During the acquisition process, thumbnail images can be generated in real time and the data can be automatically processed | |
| Data processing | An automatic reference for multiple spectrograms, with batch processing function, allowing one-click processing of multiple samples | |
| Report | New and edit report templates are available. Reports can automatically generate curves and data for each point on the curves. They can also automatically generate statistics for multiple samples. Multiple functions such as printing sequences are available | |
| Compliance Management | It has an audit tracking function and can quickly query audit records by category; it has digital signature and online approval functions, enabling paperless office work; It has an installation certification function and can automatically detect and issue IQ reports |
application
![]()
FAQ
1. who are we?
We are based in Shanghai, China, start from 2017,sell to North America(20.00%),Western Europe(15.00%),South
America(10.00%),Oceania(10.00%),Northern Europe(10.00%),Eastern Europe(10.00%),South Asia(5.00%),Southern Europe(5.00%),Central
America(5.00%),Africa(5.00%),Southeast Asia(5.00%). There are total about 5-10 people in our office.
2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3.what can you buy from us?
Differential Scanning Calorimeter, Thermogravimetric Analyzer, Differential Thermal Analyzer, Oxygen Bomb Calorimeter, Spot Cooler
4. why should you buy from us not from other suppliers?
We have 10 years of experience in design and development. The price preferential benefit There is a lot of goods in stock The
service is good
5. what services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,FAS,CIP,FCA,DDU,Express Delivery,DAF;
Accepted Payment Currency:USD;
Accepted Payment Type: T/T,Credit Card,Western Union;
Language Spoken:English,Chinese