Color: | Gray | Power: | 220V50Hz |
---|---|---|---|
Function: | Measure The Calorific Power Of Material | Warranty: | 1 Year |
Dimensions: | 70*73*63(cm) | Machine Weight: | 70KG |
High Light: | calorific value measurement instrument,laboratory testing equipment |
Digital Display Oxygen Bomb Calorimeter Heat Absorption
Product advantages:
1. The environment adaptability is strong and the test results are accurate and stable.
2. The experimental data full curve tracking function, can easily view the temperature and time in the curve.
3. With instructions for operation, failure, etc., the experiment ends with automatic voice report results.
4. The window display uses a 7.0-inch color LCD touch screen, the display content is intuitive and easy to understand.
5. Simple and convenient, the control core uses ARM9 microprocessor, fast, real-time.
6. Reliability fault self-tuning function, the device has a variety of protection functions.
7. Using internal and external tube photoelectric isolation, strong anti-interference ability.
8. Internal loading has standards, instructions and common troubleshooting methods.
Working principle:
In the calorimetric system of the calorimeter, in addition to the heat absorbed by the water, the oxygen bomb, the inner cylinder, the thermometer and the agitator absorb heat, and the respective heat absorption conditions are different. Various factors are complicated, and it is impossible to rely on simple Mathematical calculations can only use the reference of known calorific value, such as benzoic acid, to actually calibrate the heat absorbed by the calorimeter system for every 1 °C increase, that is, to calibrate the calorimeter's heat capacity.
Features:
1. The user only needs to prepare the sample, experiment results statistics and other processes can be fully automated.
2. Automatically adjust the temperature difference between the inner and outer cylinders to ensure that the inner cylinder is about 1K higher than the outer cylinder temperature at the end point and the test results are stable for a long time.
3. It can carry out experiments for more than 72 hours.
4. Imported mechanical parts, automatic oxygenation, automatic deflation, automatic lifting oxygen bombs and other sports.
5. The compressor cooling and special heating device are adopted to realize the automatic control of the water temperature of the outer cylinder.
Technical Parameters:
Temperature resolution | 0.0001K |
Precision | ≦0.05% |
Conformance with Standard | ASTM D5865, ASTM D240, ASTM D4809, ASTM E711, ASTM D5468, AS 1038.5,BS EN 15400, BIS1350,ISO 1928, ISO 9831,ISO18125,GB/T 213,GB/T 30727 |
Energy Measurement Range | 0~50000J |
External water tank capacity | about 40L |
Inner water tank capacity | about 2.1L |
Temperature range | 5-40 ° C |
Power | ≦100W |
Dimensions(cm) | 70*73*63 |
Machine weight | 70KG |
Power supply voltage | AC220V 50Hz |
Single calorie measurement time | about 15 minutes |