Usage: | Measuring The Calorific Power | Energy Measurement Range: | 0~50000J |
---|---|---|---|
External Water Tank Capacity: | 40L | Inner Water Tank Capacity: | 2.1L |
Voltage: | AC220V 50Hz | Single Calorie Measurement Time: | 15 Minutes |
Highlight: | automatic calorimeter,calorific value measurement instrument |
Diesel Fuel Oil Oxygen Bomb Calorimeter
Product advantages:
1. Test results are accurate and stable.
2. The experimental data full curve tracking function.
3. The experiment ends with automatic voice report results.
4. The window display uses a 7.0-inch color LCD touch screen.
5. The control core uses ARM9 microprocessor, fast, real-time.
6. The device has a variety of protection functions.
7. Using internal and external tube photoelectric isolation, strong anti-interference ability.
8. Internal loading has standards, instructions and common troubleshooting methods.
Scope of application:
The automatic calorimeter is suitable for measuring the power, coal, metallurgy, petrochemical, quality inspection, environmental protection cement, papermaking, geological exploration, scientific research institutes and other industrial sectors. Measuring the calorific value of coal, coke, petroleum, cement, brick and other solid or liquid combustibles, in line with the national standard GB/T213-2008 "calculation method of coal calorific value".
Features:
Ultra-large capacity water tank for large batch continuous 24 hour experiment
1. The user only needs to install the oxygen bomb when the user operates, and the remaining electronic balance is used to read the sample weight, oxygen, oxygen bomb, oxygen bomb, quantitative inner cylinder water, ignition, completion test, oxygen bomb deflation, experiment Results statistics and other processes can be fully automated.
2. Automatically adjust the temperature difference between the inner and outer cylinders to ensure that the inner cylinder is about 1K higher than the outer cylinder temperature at the end point, which fully meets the requirements of the national standard 8.2.4, and the test results are stable for a long time.
3. It can carry out experiments for more than 72 hours, which solves the technical problem that the calorimeter without cooling device needs to suspend the experiment due to the increase of the outer cylinder water temperature (overshoot).
4. Imported mechanical parts, automatic oxygenation, automatic deflation, automatic lifting oxygen bombs and other sports.
5. The compressor cooling and special heating device are adopted to realize the automatic control of the water temperature of the outer cylinder, and the temperature control accuracy meets the requirements of the national standard 7.1.4 (±0.1K).
Technical Parameters:
Temperature resolution | 0.0001K |
Precision | ≦0.05% |
Conformance with Standard | ASTM D5865, ASTM D240, ASTM D4809, ASTM E711, ASTM D5468, AS 1038.5,BS EN 15400, BIS1350,ISO 1928, ISO 9831,ISO18125,GB/T 213,GB/T 30727 |
Energy Measurement Range | 0~50000J |
External water tank capacity | about 40L |
Inner water tank capacity | about 2.1L |
Temperature range | 5-40 ° C |
Power | ≦100W |
Dimensions(cm) | 70*73*63 |
Machine weight | 70KG |
Power supply voltage | AC220V 50Hz |
Single calorie measurement time | about 15 minutes |