Send Message
products

Differential Scanning Calorimetry Machine With Liquid Nitrogen Refrigeration

Basic Information
Place of Origin: CHINA
Brand Name: BAXIT
Model Number: DSC-500L
Minimum Order Quantity: 1SET
Price: Negotiable
Packaging Details: Wooden box
Delivery Time: 5-8WORK DAY
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 500 Set/Sets per Month
Detail Information
Power: Electronic Usage: Universal Testing Machine
Warranty: 1 Year Power Supply: 220V 50HZ
Certification: CE,ISO,GB Color: White
High Light:

lab testing instruments

,

lab testing equipment


Product Description

DSC-500L Differential Scanning Calorimeter/Rubber DSC Calorimeter Differential Scanning Calorimetry Machine Price


 
QUICK DETAILS
With liquid nitrogen refrigeration, the instrument achieves linear temperature reduction by controlling the flow of liquid nitrogen. The minimum temperature can be reduced to minus 150 degrees. Differential Scanning Calorimetry (DSC) as a classic thermal analysis method for thermal effects at controlled process temperatures, research and development in various types of materials and chemistry, process optimization, quality control and failure analysis, etc. The occasion has long been widely used. Using the DSC method, we can study the phase transition of inorganic materials, the melting of polymers, the crystallization process, the polymorphism of drugs, and the solid/liquid ratio of foods such as oils and fats. Meet the national standard GB/T2951.42-2008, GB/T15065-2009, GB/T17391-1998.
 
APPLICATION
Measure heat related physical and chemical changes such as glass transition temperature and melting point. Melting temperature, crystallization and crystallization heat, phase transition reaction heat, product thermal stability, curing/crosslinking, oxidation induction period, reaction kinetics, specific heat, etc.
 
ADVANTAGES
1, industrial-level widescreen touch structure, display rich information, including set temperature, sample temperature, oxygen flow, nitrogen flow, differential heat signal, a variety of switch status.
2, by controlling the flow of liquid nitrogen to achieve linear cooling, the instrument can linearly cool to minus 150 degrees.
3, USB communication interface, versatility, reliable signal is not interrupted, support self-recovery connection function.
4, the furnace body structure is compact, the heating and cooling rate can be arbitrarily adjustable, can achieve linear cooling and linear heating function. Meet GB/T 22567-2008
5, to improve the installation process, all using mechanical fixing method to completely avoid the internal body of the gel on the differential heat signal pollution.
6. High-precision imported dual temperature sensor ensures high repeatability of sample temperature measurement.
7. The digital gas mass flowmeter automatically switches two air flow rates, with fast switching speed and short settling time.
8, standard standard sample, to facilitate the customer to calibrate the temperature coefficient.
9, software adaptive resolution of the computer screen; support notebooks, desktops, support WIN2000, XP, WIN7, WIN8, WIN10 and other operating systems.
10, support for user self-programming program, to achieve full automation of the measurement process. The software provides dozens of instructions. The user can flexibly combine the instructions according to their own measurement procedures and save them. Complex operations are simplified into one-click operation.
 
Differential Scanning Calorimetry Machine With Liquid Nitrogen Refrigeration 0
Differential Scanning Calorimetry Machine With Liquid Nitrogen Refrigeration 1
Differential Scanning Calorimetry Machine With Liquid Nitrogen Refrigeration 2
Differential Scanning Calorimetry Machine With Liquid Nitrogen Refrigeration 3
 
TECHNICAL PARAMETERS

Model DSC-500L
Temperature range: -150~500°C
DSC range: 0~±500mW
Heating rate: 0.1~50°C/min
Cooling rate: 0.1~10°C/min
Temperature Resolution: 0.01°C
Temperature accuracy: ±0.1°C
Temperature repeatability: ±0.1°C
DSC Accuracy: ±1%
DSC Resolution: 0.1uW
Temperature control mode: Temperature increase, constant temperature, cooling, cycle temperature control (full program automatic control)
Curve Scan: Warming Scan
Atmosphere control: Gas mass flowmeter automatically switches two gases
Display mode: 24bit color, 7-inch LED touch screen display
Data Interface: USB standard interface, supporting the corresponding operating software
Parameter Standards: With standard calibrators, with one-key calibration function, users can calibrate their own temperature
Working power supply: AC220V 50Hz/60Hz

 

Packaging & Shipping
1. Aluminium box and carton box, careful and tight package, make sure the package is intact

2. The package will be shipped by DHL/Fedex/TNT/EMS/UPS/China post/EF-Express/Special line, as you have chose in the order.
Differential Scanning Calorimetry Machine With Liquid Nitrogen Refrigeration 4
Our Services

If you encounter with any problems during the testing process,we promise providing urgent guidence and after-sales sevice within 48 hours and solution providing within 3 working days. If customers require on-site service, the transport and travel expense shall be responsible for the cost.
1. Pre-service
24 Hours online service for customers' consultation.
2. Middle service
-- Fullfill customer's request:
-- Payment method depends on customer.
-- Promptly production and delivery
-- Can provide invoice value if you want to decrease your tax.
3. After sale service
-- One year warranty service and all life maintenance.
-- Technical Egineer are avalible for oversea trainning.
-- Remote control technical consult

Contact Details
Clarke

Phone Number : +8615001723665

WhatsApp : +8615001723665