Send Message
products

Cold Crystallization DSC Differential Scanning Calorimeter

Basic Information
Place of Origin: CHINA
Brand Name: BAXIT
Model Number: GLO-AD09
Minimum Order Quantity: 1SET
Price: Negotiable
Packaging Details: Wooden box
Delivery Time: 5-8WORK DAY
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 500 Set/Sets per Month
Detail Information
Working Power Supply: AC220V 50Hz/60Hz DSC Range: 0~±500mW
Temperature Range: -150~500°C Heating Rate: 0.1~50°C/min
Cooling Rate: 0.1~10°C/min
High Light:

DSC Differential Scanning Calorimeter

,

Cold Crystallization Differential Scanning Calorimeter

,

AC220V Differential Scanning Calorimeter


Product Description

TOP1 High-quality DSC analyzer differential scanning calorimeter thermal analyzer by Glomro


 
QUICK DETAILS

DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, oxidation induction time (OIT).
 
APPLICATION
Measure heat related physical and chemical changes such as glass transition temperature and melting point. Melting temperature, crystallization and crystallization heat, phase transition reaction heat, product thermal stability, curing/crosslinking, oxidation induction period, reaction kinetics, specific heat, etc.
 
ADVANTAGES

1, Widescreen touch structure of industrial level, rich display information, including the set temperature, sample temperature, oxygen flow rate,Nitrogen flow, differential thermal signals, all kinds of switch state, flow goes to zero.
2, By controlling the flow of liquid nitrogen to achieve linear cooling, the instrument can linearly cool to minus 150 degrees.
3,
USB communication interface, generality is strong, reliable communication don't interrupt, support the restore connection function.
4, the furnace body structure is compact, the heating and cooling rate can be arbitrarily adjustable, can achieve linear cooling and linear heating function. Meet GB/T 22567-2008
5,
Improved installation process, all adopt the machinery fixed way, completely to avoid contamination of furnace inside colloid to differential thermal signal.
6. High-precision imported dual temperature sensor ensures high repeatability of sample temperature measurement.
7. The digital gas mass flowmeter automatically switches two air flow rates, with fast switching speed and short settling time.
8, standard standard sample, to facilitate the customer to calibrate the temperature coefficient.
9, software adaptive resolution of the computer screen; support notebooks, desktops, support WIN2000, XP, WIN7, WIN8, WIN10 and other operating systems.
10, support for user self-programming program, to achieve full automation of the measurement process. The software provides dozens of instructions. The user can flexibly combine the instructions according to their own measurement procedures and save them. Complex operations are simplified into one-click operation.
 
Cold Crystallization DSC Differential Scanning Calorimeter 0

 

Cold Crystallization DSC Differential Scanning Calorimeter 1

Cold Crystallization DSC Differential Scanning Calorimeter 2
 

 

Technical Parameter

DSC range: 0~±500mW
Temperature range: -150~500°C
Heating rate: 0.1~50°C/min
Cooling rate: 0.1~10°C/min
Temperature Resolution: 0.01°C
Temperature accuracy: ±0.1°C
Temperature repeatability: ±0.1°C
DSC Accuracy: ±1%
DSC Resolution: 0.1uW
Temperature control mode: Temperature increase, constant temperature, cooling, cycle temperature control (full program automatic control)
Curve Scan: Warming Scan
Atmosphere control: Gas mass flowmeter automatically switches two gases
Display mode: 24bit color, 7-inch LED touch screen display
Data Interface: USB standard interface, supporting the corresponding operating software
Parameter Standards: With standard calibrators, with one-key calibration function, users can calibrate their own temperature
Working power supply: AC220V 50Hz/60Hz
 

 

Packaging & Shipping
1. Aluminium box and carton box, careful and tight package, make sure the package is intact

2. The package will be shipped by DHL/Fedex/TNT/EMS/UPS/China post/EF-Express/Special line, as you have chose in the order.
Cold Crystallization DSC Differential Scanning Calorimeter 3
Our Services

If you encounter with any problems during the testing process,we promise providing urgent guidence and after-sales sevice within 48 hours and solution providing within 3 working days. If customers require on-site service, the transport and travel expense shall be responsible for the cost.
1. Pre-service
24 Hours online service for customers' consultation.
2. Middle service
-- Fullfill customer's request:
-- Payment method depends on customer.
-- Promptly production and delivery
-- Can provide invoice value if you want to decrease your tax.
3. After sale service
-- One year warranty service and all life maintenance.
-- Technical Egineer are avalible for oversea trainning.
-- Remote control technical consult

Contact Details
Clarke

Phone Number : +8615001723665

WhatsApp : +8615001723665